Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.441
Filtrar
1.
Sci Rep ; 14(1): 7962, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575628

RESUMO

The underlying study was carried out aiming at transdermal drug delivery (TDD) of Goniothalamus macrophyllus as sono-photo-sensitizer (SPS) using microneedle (MN) arrays with iontophoresis (MN-IP), electroporation (MN-EP) in conjunction with applying photodynamic therapy (PDT), sonodynamic therapy (SDT) and sono-photodynamic therapy (SPDT) as an up-to-date activated cancer treatment modality. Study was conducted on 120 male Swiss Albino mice, inoculated with Ehrlich ascites carcinoma (EAC) divided into 9 groups. We employed three different arrays of MN electrodes were used (parallel, triangular, and circular), EP, IP with different volts (6, 9, 12 V), an infrared laser and an ultrasound (pulsed and continuous wave) as our two energy sources. Results revealed that parallel 6 V TDD@MN@IP@EP can be used as effective delivery system for G. macrophyllus from skin directly to target EAC cells. In addition MN@IP@EP@TDD G. macrophyllus is a potential SPS for SPDT treatment of EAC. With respect to normal control mice and as opposed to the EAC untreated control mice, MN@EP@IP TDD G. macrophyllus in the laser, ultrasound, and combination activated groups showed a significant increase in the antioxidant markers TAC level and the GST, GR, Catalase, and SOD activities, while decrease in lipid peroxidation oxidative stress parameter MDA levels. In addition significantly increased apoptotic genes expressions (p53, caspase (3, 9), Bax, and TNF alpha) and on the other hand decreased anti- apoptotic (Bcl-2) and angiogenic (VEGF) genes expressions. Moreover significantly ameliorate liver and kidney function decreasing ALT, AST, urea and creatinine respectively. Furthermore MN@IP@EP@TDD G. macrophyllus combined with SPDT was very effective at reducing the growth of tumors and even causing cell death according to microscopic H&E stain results. This process may be related to a sono- and/or photochemical activation mechanism. According to the findings, MN@IP@EP@TDD G. macrophyllus has a lot of potential as a novel, efficient delivery method that in combination with infrared laser and ultrasound activation SPDT demonstrated promising anticancer impact for treating cancer.


Assuntos
Carcinoma , Goniothalamus , Masculino , Animais , Camundongos , Iontoforese , Administração Cutânea , Pele/metabolismo , Eletroporação/métodos , Carcinoma/metabolismo
2.
J Vis Exp ; (205)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38557598

RESUMO

Genome editing technology is widely used to produce genetically modified animals, including rats. Cytoplasmic or pronuclear injection of DNA repair templates and CRISPR-Cas reagents is the most common delivery method into embryos. However, this type of micromanipulation necessitates access to specialized equipment, is laborious, and requires a certain level of technical skill. Moreover, microinjection techniques often result in lower embryo survival due to the mechanical stress on the embryo. In this protocol, we developed an optimized method to deliver large DNA repair templates to work in conjunction with CRISPR-Cas9 genome editing without the need for microinjection. This protocol combines AAV-mediated DNA delivery of single-stranded DNA donor templates along with the delivery of CRISPR-Cas9 ribonucleoprotein (RNP) by electroporation to modify 2-cell embryos. Using this novel strategy, we have successfully produced targeted knock-in rat models carrying insertion of DNA sequences from 1.2 to 3.0 kb in size with efficiencies between 42% and 90%.


Assuntos
Sistemas CRISPR-Cas , Edição de Genes , Ratos , Animais , Edição de Genes/métodos , Dependovirus/genética , Eletroporação/métodos , Zigoto
3.
Biotechnol J ; 19(4): e2300475, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38651262

RESUMO

The application of pulsed electric fields (PEFs) is becoming a promising tool for application in biotechnology, and the food industry. However, real-time monitoring of the efficiency of PEF treatment conditions is challenging, especially at the industrial scale and in continuous production conditions.  To overcome this challenge, we have developed a straightforward setup capable of real-time detection of yeast biological autoluminescence (BAL) during pulsing. Saccharomyces cerevisiae culture was exposed to 8 pulses of 100 µs width with electric field strength magnitude 2-7 kV cm-1. To assess the sensitivity of our method in detecting yeast electroporation, we conducted a comparison with established methods including impedance measurements, propidium iodide uptake, cell growth assay, and fluorescence microscopy. Our results demonstrate that yeast electroporation can be instantaneously monitored during pulsing, making it highly suitable for industrial applications. Furthermore, the simplicity of our setup facilitates its integration into continuous liquid flow systems. Additionally, we have established quantitative indicators based on a thorough statistical analysis of the data that can be implemented through a dedicated machine interface, providing efficiency indicators for analysis.


Assuntos
Eletroporação , Saccharomyces cerevisiae , Saccharomyces cerevisiae/crescimento & desenvolvimento , Eletroporação/métodos
4.
J Vis Exp ; (205)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38526071

RESUMO

During the development of the cerebral cortex, neurons and glial cells originate in the ventricular zone lining the ventricle and migrate toward the brain surface. This process is crucial for proper brain function, and its dysregulation can result in neurodevelopmental and psychiatric disorders after birth. In fact, many genes responsible for these diseases have been found to be involved in this process, and therefore, revealing how these mutations affect cellular dynamics is important for understanding the pathogenesis of these diseases. This protocol introduces a technique for time-lapse imaging of migrating neurons and glial progenitors in brain slices obtained from mouse embryos. Cells are labeled with fluorescent proteins using in utero electroporation, which visualizes individual cells migrating from the ventricular zone with a high signal-to-noise ratio. Moreover, this in vivo gene transfer system enables us to easily perform gain-of-function or loss-of-function experiments on the given genes by co-electroporation of their expression or knockdown/knockout vectors. Using this protocol, the migratory behavior and migration speed of individual cells, information that is never obtained from fixed brains, can be analyzed.


Assuntos
Neuroglia , Neurônios , Humanos , Animais , Camundongos , Imagem com Lapso de Tempo/métodos , Movimento Celular/fisiologia , Neurônios/fisiologia , Encéfalo , Córtex Cerebral , Eletroporação/métodos
5.
STAR Protoc ; 5(1): 102940, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38460133

RESUMO

The use of CRISPR-Cas9 ribonucleoproteins has revolutionized manipulation of genomes. Here, we present a protocol for the electroporation of CRISPR-Cas for DNA and RNA targeting in Bos taurus zygotes. First, we describe steps for production and preparation of presumptive zygotes for electroporation. The first electroporation introduces ribonucleoproteins formed by Cas9D10A with two guide RNAs to target DNA, and the second introduces the same ribonucleoprotein complex to target DNA plus Cas13a with one guide RNA to target RNAs. For complete details on the use and execution of this protocol, please refer to Nix et al.1.


Assuntos
Sistemas CRISPR-Cas , Zigoto , Bovinos , Animais , Sistemas CRISPR-Cas/genética , Edição de Genes/métodos , RNA Guia de Sistemas CRISPR-Cas , RNA/genética , Eletroporação/métodos , DNA/genética , Ribonucleoproteínas/genética
6.
BMC Biotechnol ; 24(1): 16, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532411

RESUMO

BACKGROUND: Cytotoxic T lymphocytes (CTLs) are central players in the adaptive immune response. Their functional characterization and clinical research depend on efficient and reliable transfection. Although various methods have been utilized, electroporation remains the preferred technique for transient gene over-expression. However, the efficiency of electroporation is reduced for human and mouse primary CTLs. Lonza offers kits that effectively improve plasmid DNA transfection quality. Unfortunately, the removal of key components of the cell recovery medium considerably reduced the efficiency of their kit for CTLs. Our aim was to develop a new recovery medium to be used with Lonza's Nucleofector system that would significantly enhance transfection rates. RESULTS: We assessed the impact of different media in which the primary CTLs were placed to recover after electroporation on cell survival, transfection rate and their ability to form an immunological synapse and to perform exocytosis. We transfected the cells with pmax-GFP and large constructs encoding for either CD81-super ecliptic pHluorin or granzyme B-pHuji. The comparison of five different media for mouse and two for human CTLs demonstrated that our new recovery medium composed of Opti-MEM-GlutaMAX supplemented with HEPES, DMSO and sodium pyruvate gave the best result in cell survival (> 50%) and transfection rate (> 30 and 20% for mouse and human cells, respectively). More importantly, the functionality of CTLs was at least twice as high as with the original Lonza recovery medium. In addition, our RM significantly improved transfection efficacy of natural killer cells that are notoriously hard to electroporate. CONCLUSION: Our results show that successful transfection depends not only on the electroporation medium and pulse sequence but also on the medium applied for cell recovery. In addition, we have reduced our reliance on proprietary products by designing an effective recovery medium for both mouse and human primary CTLs and other lymphocytes that can be easily implemented by any laboratory. We expect that this recovery medium will have a significant impact on both fundamental and applied research in immunology.


Assuntos
Eletroporação , Linfócitos T Citotóxicos , Humanos , Camundongos , Animais , Eletroporação/métodos , Transfecção , Plasmídeos , DNA/genética
7.
Int J Mol Sci ; 25(6)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38542122

RESUMO

Gene electrotransfer (GET) of plasmids encoding interleukin 12 (IL-12) has already been used for the treatment of various types of tumors in human oncology and as an adjuvant in DNA vaccines. In recent years, we have developed a plasmid encoding human IL-12 (phIL12) that is currently in a phase I clinical study. The aim was to confirm the results of a non-clinical study in mice on pharmacokinetic characteristics and safety in a porcine model that better resembled human skin. The GET of phIL12 in the skin was performed on nine pigs using different concentrations of plasmid phIL12 and invasive (needle) or noninvasive (plate) types of electrodes. The results of our study demonstrate that the GET of phIL-12 with needle electrodes induced the highest expression of IL-12 at the protein level on day 7 after the procedure. The plasmid was distributed to all tested organs; however, its amount decreased over time and was at a minimum 28 days after GET. Based on plasmid copy number and expression results, together with blood analysis, we showed that IL-12 GET is safe in a porcine animal model. Furthermore, we demonstrated that pigs are a valuable model for human gene therapy safety studies.


Assuntos
Técnicas de Transferência de Genes , Interleucina-12 , Humanos , Animais , Camundongos , Suínos , Interleucina-12/genética , Interleucina-12/metabolismo , Transfecção , Terapia Genética/métodos , DNA/metabolismo , Plasmídeos/genética , Vacinação , Eletroporação/métodos
8.
J Microbiol Methods ; 220: 106912, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38452904

RESUMO

Electroporation is a vital process that facilitates the use of modern recombineering and other high-throughput techniques in a wide array of microorganisms, including non-model bacteria like plant growth-promoting bacteria (PGPB). These microorganisms play a significant role in plant health by colonizing plants and promoting growth through nutrient exchange and hormonal regulation. In this study, we introduce a sequential Design of Experiments (DOE) approach to obtain highly competent cells swiftly and reliably for electroporation. Our method focuses on optimizing the three stages of the electroporation procedure-preparing competent cells, applying the electric pulse field, and recovering transformed cells-separately. We utilized a split-plot fractional design with five factors and a covariate to optimize the first step, response surface methodology (RSM) for the second step, and Plackett-Burman design for two categorical factors and one continuous factor for the final step. Following the experimental sequence with three bacterial models, we achieved efficiencies 10 to 100 times higher, reaching orders of 105 to 106 CFU/µg of circular plasmid DNA. These results highlight the significant potential for enhancing electroporation protocols for non-model bacteria.


Assuntos
DNA , Transformação Bacteriana , Plasmídeos , Eletroporação/métodos , Plantas , Bactérias/genética
9.
Biomed Phys Eng Express ; 10(3)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38479001

RESUMO

We present a numerical method for studying reversible electroporation on normal and cancerous cervical cells. This microdosimetry analysis builds on a unique approach for extracting contours of free and overlapping cervical cells in the cluster from the Extended Depth of Field (EDF) images. The algorithm used for extracting the contours is a joint optimization of multiple-level set function along with the Gaussian mixture model and Maximally Stable Extremal Regions. These contours are then exported to a multi-physics domain solver, where a variable frequency pulsed electric field is applied. The trans-Membrane voltage (TMV) developed across the cell membrane is computed using the Maxwell equation coupled with a statistical approach, employing the asymptotic Smoluchowski equation. The numerical model was validated by successful replication of existing experimental configurations that employed low-frequency uni-polar pulses on the overlapping cells to obtain reversible electroporation, wherein, several overlapping clumps of cervical cells were targeted. For high-frequency calculation, a combination of normal and cancerous cells is introduced to the computational domain. The cells are assumed to be dispersive and the Debye dispersion equation is used for further calculations. We also present the resulting strength-duration relationship for achieving the threshold value of electroporation between the normal and cancerous cervical cells due to their size and conductivity differences. The dye uptake modulation during the high-frequency electric field electroporation is further advocated by a mathematical model.


Assuntos
Eletricidade , Modelos Teóricos , Membrana Celular/metabolismo , Condutividade Elétrica , Eletroporação/métodos
10.
Cancer Med ; 13(5): e7035, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38491833

RESUMO

BACKGROUND: Malignant liver tumors seriously endanger human health. Among different therapeutic approaches, high-frequency irreversible electroporation (H-FIRE) is a recently emerging tumor ablation technique. The objective of this study was to evaluate the feasibility and safety of ultrasound-guided percutaneous H-FIRE using four electrode needles in porcine livers. METHODS: Twelve experimental pigs underwent percutaneous H-FIRE ablation using a compound steep-pulse therapeutic device. Liver tissues adjacent to the gallbladder, blood vessels, and bile ducts were selected as the ablation targets. Pigs were randomly divided into three groups: (1) immediately after ablation (N = 4), (2) 2 days after ablation (N = 4), and (3) 7 days after ablation (N = 4). Blood routine, liver and kidney function, and myocardial enzyme levels were measured before and after ablation. Ultrasound, contrast-enhanced ultrasound (CEUS), contrast-enhanced magnetic resonance imaging (MRI), and hematoxylin-eosin staining were performed to evaluate the ablation performance. RESULTS: Ultrasound-guided percutaneous H-FIRE ablations using four electrode needles were successfully performed in all 12 experimental pigs. The general conditions of the pigs, including postoperative activities and feeding behaviors, were normal, with no significant changes compared with the preoperative conditions. The imaging features of ultrasound, CEUS, and MRI demonstrated no significant changes in the gallbladder walls, bile ducts, or blood vessels close to the ablation areas. Laboratory tests showed that liver function indices and myocardial enzymes increased temporarily after H-FIRE ablation, but decreased to normal levels at 7 days after ablation. Histopathological examinations of porcine liver specimens showed that this technique could effectively ablate the target areas without damaging the surrounding or internal vascular systems and gallbladder. CONCLUSIONS: This study demonstrated the feasibility and safety of ultrasound-guided percutaneous H-FIRE ablation in porcine livers in vivo, and proposed a four-needle method to optimize its clinical application.


Assuntos
Fígado , Ultrassonografia de Intervenção , Animais , Eletrodos , Eletroporação/métodos , Estudos de Viabilidade , Fígado/diagnóstico por imagem , Fígado/cirurgia , Suínos
11.
Lab Chip ; 24(7): 1957-1964, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38353261

RESUMO

Electroporation (in which the permeability of a cell membrane is increased transiently by exposure to an appropriate electric field) has exhibited great potential of becoming an alternative to adeno-associated virus (AAV)-based retina gene delivery. Electroporation eliminates the safety concerns of employing exogenous viruses and exceeds the limit of AAV cargo size. Unfortunately, several concerns (e.g., relatively high electroporation voltage, poor surgical operability and a lack of spatial selectivity of retina tissue) have prevented electroporation from being approved for clinical application (or even clinical trials). In this study, a flexible micro-electrode array for retina electroporation (FERE) was developed for retina electroporation. A suitably shaped flexible substrate and well-placed micro-electrodes were designed to adapt to the retina curvature and generate an evenly distributed electric field on the retina with a significantly reduced electroporation voltage of 5 V. The FERE provided (for the first time) a capability of controlled gene delivery to the different structural layers of retina tissue by precise control of the distribution of the electrical field. After ensuring the surgical operability of the FERE on rabbit eyeballs, the FERE was verified to be capable of transfecting different layers of retina tissue with satisfactory efficiency and minimum damage. Our method bridges the technical gap between laboratory validation and clinical use of retina electroporation.


Assuntos
Eletroporação , Retina , Animais , Coelhos , Eletroporação/métodos , Eletrodos , Técnicas de Transferência de Genes , Transfecção
12.
Mol Pharm ; 21(4): 1998-2011, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38412284

RESUMO

Pancreatic cancer is a deadly disease with a five-year overall survival rate of around 11%. Chemotherapy is a cornerstone in the treatment of this malignancy, but the intratumoral delivery of chemotherapy drugs is impaired by the highly fibrotic tumor-associated stroma. Irreversible electroporation (IRE) is an ablative technique for treating locally advanced pancreatic cancer. During a typical IRE procedure, high-intensity electric pulses are released to kill tumor cells through the irreversible disruption of the cytoplasm membranes. IRE also induces rapid tumor infiltration by neutrophils and offers an opportunity for neutrophil-mediated drug delivery. We herein showed that the IRE-induced neutrophil trafficking was facilitated by the upregulation of neutrophil chemotaxis and migration as well as the release of several chemoattractants. Doxorubicin-loaded bovine serum albumin nanoparticles were prepared and loaded into neutrophils at a ratio of 9.9 ± 1.2 to 11.7 ± 2.0 pg of doxorubicin per cell. The resultant formulation (NP@NEs) efficiently accumulated in the IRE-treated KPC-A377 murine pancreatic tumors with an uptake value of 10.7 ± 1.5 (percent of injected dose per gram of tissue, abbreviated as %ID/g) at 48 h after intravenous injection. In both Panc02 and KPC-A377 murine pancreatic tumor models, the combination of IRE + NP@NEs inhibited tumor growth more effectively than either monotherapy. The tumors treated with the combination also exhibited the lowest frequency of Ki67+ proliferating cells and the highest abundance of terminal deoxynucleotidyl transferase dUTP nick end labeling+ (TUNEL+) apoptotic cells among the experiment groups. Minimal treatment-associated toxicity was observed. Our findings suggest that neutrophil-mediated delivery of chemotherapy drugs is a useful tool to enhance the response of pancreatic cancer to IRE.


Assuntos
Neutrófilos , Neoplasias Pancreáticas , Humanos , Animais , Camundongos , Neoplasias Pancreáticas/patologia , Inflamação , Eletroporação/métodos , Doxorrubicina
13.
Theriogenology ; 218: 111-118, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38320372

RESUMO

Genetically modified pigs play a critical role in mimicking human diseases, xenotransplantation, and the development of pigs resistant to viral diseases. The use of programmable endonucleases, including the CRISPR/Cas9 system, has revolutionized the generation of genetically modified pigs. This study evaluates the efficiency of electroporation of oocytes prior to fertilization in generating edited gene embryos for different models. For single gene editing, phospholipase C zeta (PLC ζ) and fused in sarcoma (FUS) genes were used, and the concentration of sgRNA and Cas9 complexes was optimized. The results showed that increasing the concentration resulted in higher mutation rates without affecting the blastocyst rate. Electroporation produced double knockouts for the TPC1/TPC2 genes with high efficiency (79 %). In addition, resistance to viral diseases such as PRRS and swine influenza was achieved by electroporation, allowing the generation of double knockout embryo pigs (63 %). The study also demonstrated the potential for multiple gene editing in a single step using electroporation, which is relevant for xenotransplantation. The technique resulted in the simultaneous mutation of 5 genes (GGTA1, B4GALNT2, pseudo B4GALNT2, CMAH and GHR). Overall, electroporation proved to be an efficient and versatile method to generate genetically modified embryonic pigs, offering significant advances in biomedical and agricultural research, xenotransplantation, and disease resistance. Electroporation led to the processing of numerous oocytes in a single session using less expensive equipment. We confirmed the generation of gene-edited porcine embryos for single, double, or quintuple genes simultaneously without altering embryo development to the blastocyst stage. The results provide valuable insights into the optimization of gene editing protocols for different models, opening new avenues for research and applications in this field.


Assuntos
Doenças dos Suínos , Viroses , Humanos , Animais , Suínos/genética , Animais Geneticamente Modificados , Sistemas CRISPR-Cas , RNA Guia de Sistemas CRISPR-Cas , Edição de Genes/veterinária , Edição de Genes/métodos , Fertilização In Vitro/veterinária , Oócitos , Eletroporação/veterinária , Eletroporação/métodos , Viroses/veterinária , Doenças dos Suínos/genética
14.
Theriogenology ; 218: 126-136, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38325149

RESUMO

In reproductive biology, understanding the effects of novel techniques on early embryo development is of paramount importance. To date, the effects of electrical activation on oocytes prior to in vitro fertilization (IVF) are not well understood. The aim of this study was to investigate the effects of oocyte electroporation prior to IVF on embryo development and to differentiate between true embryos and parthenotes by using a TPCN2 knock-out (KO) male to evaluate the presence of the KO allele in the resulting blastocysts. The study consisted of three experiments. The first one examined oocyte electroporation with and without subsequent IVF and found that electroporated oocytes had higher activation rates, increased occurrence of a single pronucleus, and no effect on sperm penetration. Cleavage rates improved in electroporated oocytes, but blastocyst rates remained constant. Genotype analysis revealed a significant increase in the proportion of parthenotes in the electroporated groups compared to the IVF control (30.2 % vs. 6.8 %). The second experiment compared two electroporation media, Opti-MEM and Nuclease-Free Duplex Buffer (DB). DB induced higher oocyte degeneration rates, and lower cleavage and blastocyst rates than Opti-MEM, while parthenogenetic formation remained consistent (60.0 and 48.5 %). In the third experiment, the timing of electroporation relative to IVF was evaluated (1 h before IVF, immediately before IVF and 7 h after IVF). Electroporation immediately before IVF resulted in higher activation rates and different pronuclear proportions compared to the other timing groups. The penetration rate was higher in the immediate electroporation group, and cleavage rate improved in all electroporated groups compared to the control. Blastocyst rates remained constant. Genotyping revealed no significant differences in parthenote proportions among the timing groups, but these were higher than the control (56.25 %, 63.89 %, 51.61 %, 2.44 %, respectively), and showed higher mutation rates when electroporation was performed 7 h after IVF. Overall, this comprehensive study sheds light on the potential of electroporation for creating genetically modified embryos and the importance of media selection and timing in the process, the best media being the Opti-MEM and the more efficient timing regarding mutation rate, 7 h post-IVF, even when the parthenote formation did not differ among electroporated groups. Further studies are needed to reduce the parthenogenetic activation while maintaining high mutation rates to optimize the use of this procedure for the generation of gene-edited pig embryos by oocyte/zygote electroporation.


Assuntos
Edição de Genes , Sêmen , Masculino , Animais , Suínos , Edição de Genes/veterinária , Partenogênese , Oócitos/fisiologia , Desenvolvimento Embrionário/fisiologia , Eletroporação/veterinária , Eletroporação/métodos , Blastocisto/fisiologia , Fertilização In Vitro/veterinária
15.
Sci Rep ; 14(1): 4631, 2024 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409237

RESUMO

Of all methods exercised in modern molecular biology, modification of cellular properties through the introduction or removal of nucleic acids is one of the most fundamental. As such, several methods have arisen to promote this process; these include the condensation of nucleic acids with calcium, polyethylenimine or modified lipids, electroporation, viral production, biolistics, and microinjection. An ideal transfection method would be (1) low cost, (2) exhibit high levels of biological safety, (3) offer improved efficacy over existing methods, (4) lack requirements for ongoing consumables, (5) work efficiently at any scale, (6) work efficiently on cells that are difficult to transfect by other methods, and (7) be capable of utilizing the widest array of existing genetic resources to facilitate its utility in research, biotechnical and clinical settings. To address such issues, we describe here Pressure-jump-poration (PJP), a method using rapid depressurization to transfect even difficult to modify primary cell types such as embryonic stem cells. The results demonstrate that PJP can be used to introduce an array of genetic modifiers in a safe, sterile manner. Finally, PJP-induced transfection in primary versus transformed cells reveals a surprising dichotomy between these classes which may provide further insight into the process of cellular transformation.


Assuntos
Eletroporação , Ácidos Nucleicos , Pressão Hidrostática , Transfecção , Eletroporação/métodos , Células Cultivadas
16.
Bioelectrochemistry ; 157: 108670, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38364517

RESUMO

The understanding of the mechanisms involved in DNA electrotransfer in human skin remains modest and limits the clinical development of various biomedical applications, such as DNA vaccination. To elucidate some mechanisms of DNA transfer in the skin following electroporation, we created a model of the dermis using a tissue engineering approach. This model allowed us to study the electrotransfection of fibroblasts in a three-dimensional environment that included multiple layers of fibroblasts as well as the self-secreted collagen matrix. With the aim of improving transfection yield, we applied electrical pulses with electric field lines perpendicular to the reconstructed model tissue. Our results indicate that the fibroblasts of the reconstructed skin tissue can be efficiently permeabilized by applied millisecond electrical pulses. However, despite efficient permeabilization, the transfected cells remain localized only on the surface of the microtissue, to which the plasmid was deposited. Second harmonic generation microscopy revealed the extensive extracellular collagen matrix around the fibroblasts, which might have affected the mobility of the plasmid into deeper layers of the skin tissue model. Our results show that the used skin tissue model reproduces the structural barriers that might be responsible for the limited gene electrotransfer in the skin.


Assuntos
DNA , Eletroporação , Humanos , Transfecção , Eletroporação/métodos , DNA/genética , Plasmídeos/genética , Colágeno/genética , Fibroblastos
17.
Radiología (Madr., Ed. impr.) ; 66(1): 47-56, Ene-Feb, 2024. ilus
Artigo em Espanhol | IBECS | ID: ibc-229645

RESUMO

La electroporación irreversible o IRE (irreversible electroporation) es una técnica de ablación tumoral no térmica basada en la aplicación de pulsos eléctricos de alto voltaje entre pares de agujas insertadas alrededor de un tumor. La corriente generada favorece la creación de nanoporos en la membrana plasmática, desencadenando la apoptosis. Por ello, la IRE puede utilizarse de manera segura en localizaciones cercanas a estructuras vasculares delicadas, contraindicadas para el resto de técnicas termoablativas. Actualmente la IRE se emplea con éxito para la ablación de tumores en páncreas, riñón e hígado y, de manera muy extendida, como opción terapéutica focal para el cáncer de próstata. La necesidad de un manejo anestésico específico y la colocación precisa y en paralelo de múltiples agujas implican un alto nivel de complejidad, siendo necesaria una gran experiencia del equipo intervencionista. No obstante, se trata de una técnica muy prometedora con una gran capacidad inmunológica sistémica que puede provocar un efecto a distancia del tumor tratado (efecto abscopal).(AU)


Irreversible electroporation (IRE) is a non-thermal tumor ablation technique. High-voltage electrical pulses are applied between pairs of electrodes inserted around and/or inside a tumor. The generated electric current induces the creation of nanopores in the cell membrane, triggering apoptosis. As a result, IRE can be safely used in areas near delicate vascular structures where other thermal ablation methods are contraindicated. Currently, IRE has demonstrated to be a successful ablation technique for pancreatic, renal, and liver tumors and is widely used as a focal therapeutic option for prostate cancer. The need for specific anesthetic management and accurate parallel placement of multiple electrodes entails a high level of complexity and great expertise from the interventional team is required. Nevertheless, IRE is a very promising technique with a remarkable systemic immunological capability and may impact on distant metastases (abscopal effect).(AU)


Assuntos
Humanos , Masculino , Feminino , Eletroporação/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Imunoterapia , Radiologia Intervencionista , Radiologia , Diagnóstico por Imagem , Oncologia , Técnicas de Ablação , Anestesia/métodos
18.
Radiologia (Engl Ed) ; 66(1): 47-56, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38365354

RESUMO

Irreversible Electroporation (IRE) is a non-thermal tumor ablation technique. High-voltage electrical pulses are applied between pairs of electrodes inserted around and/or inside a tumor. The generated electric current induces the creation of nanopores in the cell membrane, triggering apoptosis. As a result, IRE can be safely used in areas near delicate vascular structures where other thermal ablation methods are contraindicated. Currently, IRE has demonstrated to be a successful ablation technique for pancreatic, renal, and liver tumors and is widely used as a focal therapeutic option for prostate cancer. The need for specific anesthetic management and accurate parallel placement of multiple electrodes entails a high level of complexity and great expertise from the interventional team is required. Nevertheless, IRE is a very promising technique with a remarkable systemic immunological capability and may impact on distant metastases (abscopal effect).


Assuntos
Técnicas de Ablação , Neoplasias Hepáticas , Neoplasias da Próstata , Masculino , Humanos , Técnicas de Ablação/métodos , Eletroporação/métodos , Pâncreas
19.
Lab Chip ; 24(4): 819-831, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38235543

RESUMO

Localized micro/nano-electroporation (MEP/NEP) shows tremendous potential in cell transfection with high cell viability, precise dose control, and good transfection efficacy. In MEP/NEP, micro or nanochannels are used to tailor the electric field distribution. Cells are positioned tightly by a micron or nanochannel, and the cargoes are delivered into the cell via the channel by electrophoresis (EP). Such confined geometries with micro and nanochannels are also widely used in sorting, isolation, and condensing of biomolecules and cells. Theoretical studies on the electrokinetic phenomena in these applications have been well established. However, for MEP/NEP applications, electrokinetic phenomena and their impact on the cell transfection efficiency and cell survival rate have not been studied comprehensively. In this work, we reveal the coupling between electric field, Joule heating, electroosmosis (EO), and EP in MEP/NEP at different channel sizes. A microfluidic biochip is used to investigate the electrokinetic phenomena in MEP/NEP on a single cell level. Bubble formation is observed at a threshold voltage due to Joule heating. The bubble is pushed to the cargo side due to EO and grows at the outlet of the nanochannel. As the voltage increases, the cargo transport efficiency decreases due to more intense EO, particularly for plasmid DNAs (3.5 kbp) with a low EP mobility. An 'electroporation zone' is defined for NEP/MEP systems with different channel sizes to avoid bubble formation and excessive EO velocity that may reduce the cargo delivery efficiency.


Assuntos
Eletro-Osmose , Calefação , Eletroporação/métodos , Transfecção , Microfluídica
20.
Bioelectrochemistry ; 157: 108637, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38215652

RESUMO

The cellular membrane serves as a pivotal barrier in regulating intra- and extracellular matter exchange. Disruption of this barrier through pulsed electric fields (PEFs) induces the transmembrane transport of ions and molecules, creating a concentration gradient that subsequently results in the imbalance of cellular osmolality. In this study, a multiphysics model was developed to simulate the electromechanical response of cells exposed to microsecond pulsed electric fields (µsPEFs). Within the proposed model, the diffusion coefficient of the cellular membrane for various ions was adjusted based on electropore density. Cellular osmolality was governed and described using Van't Hoff theory, subsequently converted to loop stress to dynamically represent the cell swelling process. Validation of the model was conducted through a hypotonic experiment and simulation at 200 mOsm/kg, revealing a 14.2% increase in the cell's equivalent radius, thereby confirming the feasibility of the cell mechanical model. With the transmembrane transport of ions induced by the applied µsPEF, the hoop stress acting on the cellular membrane reached 179.95 Pa, and the cell equivalent radius increased by 11.0% when the extra-cellular medium was supplied with normal saline. The multiphysics model established in this study accurately predicts the dynamic changes in cell volume resulting from osmotic imbalance induced by PEF action. This model holds theoretical significance, offering valuable references for research on drug delivery and tumor microenvironment modulation.


Assuntos
Eletricidade , Eletroporação , Eletroporação/métodos , Membrana Celular/metabolismo , Modelos Teóricos , Íons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...